Wireless
Thermostats
17
The AC-83 is a two-channel receiver communi-
cating with detectors in the JA-80 Oasis system.
The receiver is powered by 230 V AC. It can
independently operate two heating circuits (relay
X and Y) as a receiver for TP-8x wireless thermo-
stats. The third output is used for a circulating
pump and is closed when the X relay or Y relay
is closed as well. All three relays can be activated automatically every 7 days for 6 minutes when the thermostat is
enrolled to the receiver – the so-called cleaning function. The pump is protected against blocking-up this way mostly
during the summer months. The thermostat can be combined with a PG output of a control panel for operating
the heating system remotely e.g. via SMS messages. The heater can be blocked automatically when a window is
open, if the thermostat for operating with an output is combined with door/window opening detectors or remote
con trollers. Even when the heating system is switched off remotely, the thermostat keeps the temperature above
6 °C through the AC-83. The AC-82 is a version with two outputs without a relay for operating a pump.
Communication band 868 MHz
Voltage 230 V AC, 50 Hz
Wattage approx. 1 W
Load of relays contacts max. 2.5A /250 V in total
Communication range with thermostats TP–8x
approx. 100 m (open area)
Dimensions 76 x 110 x 33 mm (antenna 35 mm)
Oasis
Heating control
Remote heater operating
Thermostat Control panel
AC-83 Boiler switching
Connectors for thermostat connecting
Power supply 230 V
Circulation pump
1
2
3
4
R
A
D
I
O
m
a
x
F
5
A
/
2
5
0
V
X Y
AC-83 Diagram of a controlled heating system
The AC-8014 is a fourteen channel receiver.
It cooperates with TP-8x thermostats, wireless
detectors of the system JA-80 and RC-8x cont-
rollers and also enables the connection of TP-87
bus thermostats. It operates with individual cir-
cuits of a multi circuit heating system when used
with wireless thermostats. The receiver can also
operate with the electro-valves of a floor heater,
electro-heating system contactor etc. The receiver
offers fourteen outputs switched by power transis-
tors. The status of all the outputs is signalled by
LED. It also has a relay output for operating a circulating pump. The output is closed when one of the fourteen (1-14)
outputs is closed as well. The receiver also has a cleaning function for a pump which activates the relay every 7 days
for 6 minutes. The activation of the heating system protects against dust settling and blocking-up the pump mainly
during the summer months. A special feature is the MODE channel, which can be operated by programmable outputs
of the control panel or by remote controller. The whole heating system can be remotely switched on/off through the
MODE channel, but the anti-freeze mode is still on and starts heating when the temperature drops below 6 °C.
Communication band 868 MHz
Voltage 230 V, 50 Hz
Stand-by consumption 0.05 A (non-working) max. 0.2 A
Maximum power 1.7 A
Load of output relay max. 10 A/230 V
Output voltage 1-14 and terminal COM 24 V DC
Output load 1-14 max. 0.4 A on output
(power in total for 1-14 cannot be higher then 1,7 A)
Communication range with thermostats TP–8x
approx. 100 m (open area)
Dimensions 258 x 214 x 77 mm
AC-8014 Multi Channel Receiver
AC-83 Universal Receiver